HH 250-500

Part Number: HH 250

Single Stage, Centrifugal, Hydraulic Driven

Assembly #1
  • Rotation: Engine or opposite engine
  • Gear ratio: 4.38 to 1 or 2.90 to 1
  • Heat-treated gears are standard
  • Tachometer/speed counter output
  • SAE “C” adapter
  • 12/24-14T involute female spline
  • Mounting angles
  • 4″ NPT suction
  • 2-1/2″ NPT discharge
Assembly #2
  • SAE “C” adapter
  • 12/24-14T involute female spline
  • Mounting angles
  • 3 – 4″ NPT suction
  • Two 2-1/2″ NPT discharge
Assembly #3
  • Mounting angles
  • Two 2-1/2″ NH, 1/4 turn, ball, valves, and caps
  • Two 3″ NH suction adapters and cap
  • 4″ NPT suction
  • Two 2-1/2″ NPT tapped openings on discharge manifolds
  • Two 2-1/2″ NPT tapped openings on suction
  • Body width: 70″ – 72″
HH 250
  • 250 gpm (946 L/M) @ 150 psi (10.3 bar)
  • 175 gpm (662 L/M) @ 200 psi (13.8 bar)
  • 125 gpm (473 L/M) @ 250 psi (17.5 bar)
HH 350
  • 350 gpm (1325 L/M) @ 150 psi (10.3 bar)
  • 245 gpm (927 L/M) @ 200 psi (13.8 bar)
  • 175 gpm (662 L/M) @ 250 psi (17.2 bar)
HH 500
  • 500 gpm (1893 L/M) @ 150 psi (10.3 bar)
  • 350 gpm (1325 L/M) @ 200 psi (13.8 bar)
  • 250 gpm (946 L/M) @ 250 psi (17.2 bar)
12″L x 19″W x 14″H 145 lbs. (66 kg)
Applications
  • Mini Pumper
  • Tanker
  • Wildland/Attack Fire

Connect with our team

Our experts are ready to help you take the next step.

Contact Us